EasyStart MicroAir 368 Soft Start Home Commercial Easy Start (ASY-368-X48), Air Conditioner Soft Start Works with Generator, Start Air Conditioners at Less Power, Home and Commercial Use - Grey
-
PB
> 24 hourInstalled this on my whole house Rheem 4 ton unit. Before install the inrush amps measured 113. After 5 learn runs the inrush was down to 29 amps. Anybody who can read the circuit diagram of their ac should be able to install this. The Bluetooth app makes doing the learn runs easy.
-
Chuck
> 24 hourMy 3 ton air conditioner was making a couple of our house lights dim when the air came on. The condenser compressor would always start with a loud noise. After I installed the Easy Start Micro Air 368 the lights dont dim anymore, and the condenser compressor is quiet! I highly recommend this product.
-
Yabo
> 24 hourSoft Starter brought down the on rush amps on my condenser from 109 amps to 27 amps. Run amps from 20 amps to 9amps. Made in USA support in Utah. Great product.
-
Robert
> 24 hourThis device reduced my inrush current that allows me run a 4 ton central unit, a 3 ton central unit and a 2hp well pump on a 15kw Generac generator. The Hutch Mountain customer service was outstanding.
-
T. Connell
> 24 hourI received the product and quickly noticed how well made it was. Installation was a breeze with only four wires, took me about ten minutes, that included me putting the required ends on. I had one question and sent a text to support. They quickly called me back, when I say quick I mean less than 3 minutes. They walked me through the setup wire by wire to confirm it was installed correctly. My start up Amos was 60 on my 3.5 ton unit. Now my start up amps is 24. Generator now powers my entire house with the ac unit.
-
Matthew L.
> 24 hourAs advertised!
-
pat
> 24 hourInstalled on my homes 3.5 Ton 16 seer Trane condensing unit ahead of summer. For the last 2 years I have been trying to identify an electrical issue which occurs when my ac cycles during my home generators weekly test. The air conditioner would run rough and very noisy, sometimes trip itself out on thermal overload. I couldn’t figure It out until I noticed the LRA was 10 amps higher than my generator is rated to produce. A YouTube video from Engineer775 I happened to catch by luck pointed me in the right direction. My results are as follows. I could not believe the RLA in the sticker is 110. I measured 109-112 through my amp clamp. Two years of a mystery why my condenser would make horrible starting noises when running on my home 20kw generator. Preliminary testing shows 24.5 max inrush according to my fluke meter (same meter from initial inrush testing) now that the soft start was installed. My running issues are gone. My lights don’t dim and my condenser runs smooth. I’m impressed to say the least. I have yet to venture into the app and the Bluetooth features but will soon.
-
D Murph
> 24 hourEasy to install. Works as advertised. Seller was great, Got my order sooner than expected.
-
keyoctave
> 24 hourI have a 3 Ton Carrier unit that is 11 years old now. First thing I did was check the max amperage before any modifications. Mine came in at 68 amps. I then replaced the original capacitor just because and checked again. The max amperage came down to 60 amp. After installing the soft start unit, starting it 5 times per instructions (have to wait a few minutes between each start) and checking, I was shocked! Max amperage was 19 amps!!! I then switched over to my 6000 watt LP generator. It starts the AC with only the slightest change in rpm’s. Wow! Was never able to do this before. I have an oil furnace that runs off the generator but never could use the heat pump or AC. Now I can do it all! The cost of the EasyStart plus generator comes out to about what one would pay for just a larger generator to run the unit as it was. So instead of paying more money for a larger more expensive generator that consumes much more fuel, I can use a smaller generator having less fuel consumption. More importantly, I will have less wear and tear on the compressor. Wish I had this on my unit when it was new. Highly recommended!
-
Stacey Waelchi
> 24 hourThis device reduced my 3.5 ton central AC startup current to 18.5A. The LRA on my unit is 79A. Not bad! The lights no longer dim when the compressor starts and there is no loud bang. Great product!